Taylors Doors manufactures Maxi Single and Double Leaf Hinged Fire Resistant doors incorporating fixed overhead Transom Panels utilizing a vermiculite core (TVC40) which is stable and contains no asbestos or mineral fibres.

Maxi Fire Doors with Transom Overhead Panels

Maxi Fire Resistant Doorsets with Overhead Transom Panels - Elevation and Section View

Maxi Fire Resistant doors are edged with an internal (nominal) 10mm solid timber edge rail to all four (4) sides.

The core used in the manufacture of our Maxi Fire Resistant doors is 38.5mm thick.

The following table outlines the approximate finished door thickness for a Maxi Fire Resistant door.

 

Door Type Facing Approximate Thickness (mm)
Maxi Paint Grade Ply 45.7

Maxi Single and Double Leaf Hinged Fire Resistant doors incorporating fixed overhead Transom Panels are special order items and not available to order on line. Get a Quote

Transom member must be filled with grout or plaster. Transom member can be manufactured as a removable section to maximise clear opening height for infrequent equipment access.

 

The following table details the maximum door size based on the doorset configuration.

 

The following table lists product limitations in accordance with AS1905.1-1997 based on standard configurations. Suitable wall types include Masonry, Plasterboard and Hebel.

Available Sizes in accordance with AS1905.1-1997, frame and transom member must be back filled.
Configuration Maximum Height x Width Maximum FRL
Door Leaf Transom Panel
Single Leaf 2400 x 1200 1200 x 1200 ---/120/30
Double Leaf 2400 x 2400 1200 x 2400 ---/120/30

Should you require, the following optional extras are available;

  • Vision panels
  • Air Grilles
  • Seal provisions (routed provision in the bottom of the door)
  • Tunnel lock provisions (a drilled cable transfer hole through the width of the door leaf for electric locks)